FilterFab F-Series Filters Remove Dry Particulates from Gas Lines |
|
All gas lines have dry contaminants (such as pipe scale, dirt, and rust) that will damage or even destroy your downstream equipment. Using a Filterfab F-Series Dry Filter will remove all forms of dry contamination, lengthening the life of your equipment and saving thousands of dollars in maintenance costs.
F-Series Dry Filters have:
- 4 different closure styles. FilterFab has designed its lid closures to make filter element changeout as easy and as fast as possible. 2" thru 6" line sizes in 180 and 285 psi ratings use a quick-opening swing-bolt lid or blind flange, while larger and higher pressure filters incorporate a blind flange with lifting lug or a lifting davit. Optional threaded high-pressure closures are also available.
- 4 pressures (MAOP). Available in 180, 285, 740 and 1480 psi.
- 7 standard line sizes. Choose from 2" to 12". Custom sizes to 24" available.
- A wide range of flowrates. 5,000 to 25,000,000 scfh.
- 2 types of filter cartridges. Our standard replaceable filter cartridge uses polyester-felted media or polyester/cellulose media, both of which remove 99.9% of all solid particles 10-microns and larger. This is well beyond the recommendations of all major manufacturers of meters and regulators. Our standard filter size is 10 microns, but filters with retention ratings as low as 0.3 micron to as high as 75 microns are available.
Call FilterFab's Sales Department for pricing and a representative in your area. Many model sizes are kept in stock for quick delivery.
FILTERS ALWAYS PAY FOR THEMSELVES |

F-Series Dry Filter

F-Series Dry Filter with Threaded Knockoff Closure
|
| |
Build a FilterFab F-Series Part Number |
|
To choose the correct FilterFab model for your application, start by building a part number. You will need to know line size and pressure rating. See this example:
 |
| |
F-Series Filter Flowrate Information |
| |
Now check the model number you have determined above against the flowchart below to make sure that your choice will handle the flowrate of your application. |
FLOWRATE
in SCFH for F-Series Filters |
| Model
Number |
Line
Pressure (in psi) |
| 1/4 |
5 |
25 |
50 |
100 |
150 |
250 |
500 |
750 |
1000 |
1200 |
1400 |
| F2M |
8400 |
11700 |
20000 |
26000 |
34000 |
41000 |
– |
– |
– |
– |
– |
– |
| F2 |
25500 |
29000 |
57000 |
72000 |
95000 |
114M |
260M |
355M |
433M |
575M |
685M |
780M |
| F3 |
50000 |
65000 |
122M |
144M |
220M |
265M |
570M |
820M |
950M |
1.2MM |
1.4MM |
1.5MM |
| F4 |
83000 |
120M |
210M |
250M |
380M |
470M |
970M |
1.3MM |
1.9MM |
2.5MM |
3.0MM |
3.3MM |
| F6 |
240M |
270M |
500M |
555M |
910M |
1.1MM |
2.0MM |
2.7MM |
3.1MM |
4.0MM |
5.0MM |
5.5MM |
| F8 |
410M |
490M |
770M |
1.0MM |
1.6MM |
2.0MM |
3.5MM |
5.0MM |
6.0MM |
8.0MM |
10MM |
11MM |
| F10 |
550M |
910M |
1.1MM |
1.9MM |
2.6MM |
3.0MM |
6.0MM |
7.5MM |
9.0MM |
12MM |
14MM |
17MM |
| F12 |
865M |
1.2MM |
2.2MM |
2.5MM |
4.0MM |
4.8MM |
8.8MM |
11MM |
14MM |
18MM |
22MM |
25MM |
|
| The flowrates listed are based on a 1/2 psi pressure drop up to 150 psi; 2 to 3 psi pressure drop at higher line pressures. |
| |
Choose a Style |
| |
Now look at the styles below the flowrate chart to see the standard body and closure style of your filter. Choose whether to print a hard copy in either Adobe .pdf or AutoCAD .dwg format. To download a .pdf or dwg file, right-click on a link and select "Save Target As..." |
| STYLE 1 – Quick-Opening Closure |
| PSI |
Line
Size |
Model
Number |
Dimensions |
Filter
Element |
Downloads |
| A |
B |
F |
pdf |
dwg* |
180 |
2" |
F2M-180F |
18" |
13" |
11" |
2525K140 |
.pdf |
.dwg |
180 |
2" |
F2-180F |
27" |
20" |
15" |
2385K140 |
.pdf |
.dwg |
180 |
3" |
F3-180F
|
32" |
25" |
18" |
2394K5 |
.pdf |
.dwg |
180 |
4" |
F4-180F |
43" |
35" |
20" |
2022K5 |
.pdf |
.dwg |
180 |
6" |
F6-180F |
42" |
30" |
24" |
2035K5 |
.pdf |
.dwg |
285 |
2" |
F2-285F |
27" |
20" |
15" |
2385K140 |
.pdf |
.dwg |
285 |
3" |
F3-285F |
32" |
25" |
18" |
2394K5 |
.pdf |
.dwg |
285 |
4" |
F4-285F |
43" |
35" |
20" |
2022K5 |
.pdf |
.dwg |
285 |
6" |
F6-285F |
42" |
30" |
24" |
2035K5 |
.pdf |
.dwg |
|

Use this illustration for dimension
measurements
in the charts. |
|
| |
| |
| STYLE 2 — Blind Flange with Lifting Lug |
| PSI |
Line
Size |
Model
Number |
Dimensions |
Filter
Element |
Downloads |
| A |
B |
F |
PDF |
DWG |
740 |
2" |
F2-740F |
26" |
19" |
15" |
2385K140 |
.pdf |
.dwg |
740 |
3" |
F3-740F |
32" |
25" |
18" |
2394K5 |
.pdf |
.dwg |
740 |
4" |
F4-740F |
38" |
30" |
20" |
2022K5 |
.pdf |
.dwg |
1480 |
2" |
F2-1480F |
27" |
20" |
15" |
2385K140 |
.pdf |
.dwg |
1480 |
3" |
F3-1480F |
33" |
26" |
18" |
2394K5 |
.pdf |
.dwg |
1480 |
4" |
F4-1480F |
38" |
30" |
20" |
2022K5 |
.pdf |
.dwg |
| Legs or ring bases are optional on all above housings. |
|

Use this illustration for dimension
measurements
in the charts. |
|
| |
| |
| STYLE 3 — Blind Flange with Lifting Davit |
| PSI |
Line
Size |
Model
Number |
Dimensions |
Filter
Element |
Downloads |
| A |
B |
F |
PDF |
DWG |
285 |
8" |
F8-285F |
47" |
33" |
28" |
2054K5 |
.pdf |
.dwg |
285 |
10" |
F10-285F |
60" |
44" |
32" |
(2)2070K5 |
.pdf |
.dwg |
285 |
12" |
F12-285F |
66" |
47" |
40" |
(2)2083K5 |
.pdf |
.dwg |
740 |
6" |
F6-740F |
40" |
29" |
24" |
2035K5 |
.pdf |
.dwg |
740 |
8" |
F8-740F |
48" |
34" |
28" |
2054K5 |
.pdf |
.dwg |
740 |
10" |
F10-740F |
61" |
45" |
32" |
(2)2070K5 |
.pdf |
.dwg |
740 |
12" |
F12-740F |
67" |
48" |
40" |
(2)2083K5 |
.pdf |
.dwg |
1480 |
6" |
F6-1480F |
41" |
29" |
24" |
2035K5 |
.pdf |
.dwg |
1480 |
8" |
F8-1480F |
49" |
35" |
28" |
2055K5 |
.pdf |
.dwg |
| Legs or ring bases are optional on all above housings. |
|

Use this illustration for dimension
measurements
in the charts. |
|
| |
| |
| STYLE 4 — Blind Flange with Hydraulic Davit |
| PSI |
Line
Size |
Model
Number |
Dimensions |
Filter
Element |
Downloads |
| A |
B |
F |
PDF |
DWG |
1480 |
10" |
F10-1480F |
62" |
46" |
32" |
(2)2070K5 |
.pdf |
.dwg |
1480 |
12" |
F12-1480F |
68" |
49" |
40" |
(2)2083K5 |
.pdf |
.dwg |
|

Use this illustration for dimension
measurements
in the charts. |
|
| |
We Love Special Designs! |
| |
Are there any special design changes we can make to the standard unit you have chosen to help you fit into a tight space, remove a particularly stubborn contaminant, resist a high temperature, or simply make your job easier?
a sketch of your requirement as an Adobe PDF or an AutoCAD DWG file. We will contact you with our suggestions. FilterFab started in business in 1983 by building special designs, so you can count on us to find a solution to your unique problem. |
| |
F2M "Miniature" Filter |
|
Our Model F2M "Miniature" filter was designed to be used in lower-flow applications where a strainer is just too coarse but your budget does not allow for our standard size F2 housing. Shown here with a full-size F2 the F2M is available with flanged inlet/outlet or either female or male pipe connections. This housing is an excellent choice for tight spaces and small meter runs in any mounting orientation.
|
|
| |
Need More Information, or Want to Place an Order? |
| |
Call 1-800-899-6927 or
a FilterFab Sales Representative to find out more about pricing, delivery lead time, optional equipment, or special design requirements. You may also want to visit our Contact Us page or send us a Request for Quotation. |
| |
ASME Information |
Housings are designed and built to ASME Boiler & Pressure Vessel Code, Section VIII, Division 1 specifications by Section IX certified welders but not U-Code stamped without an extra charge. |